{"release_id":19,"data":{"id":90405,"release_id":19,"source_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","kind":"article","fingerprint":"17a1a6195957e793e58cf4da2cf7e55facec1e9e4cd2a1a4cb8bc7e9cf01ee0b","title_en":"Concrete Identity-Testing Sampling Guidance","title_zh":"\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357","domain":"geography-urban-planning","status":"verified","assurance":null,"subtype":null,"lat":null,"lon":null,"date":"2026-10-29","payload":{"bundle_sha256":"45bf7e4a6e04877a9385caa9d5613e31f964959fced55c1117ce10170e4f73ce","checks":{"citations":"passed","translation":"passed"},"data":{"aliases":["concrete identity testing Singapore","concrete compressive strength sampling","BCA concrete sampling rate"],"aliases_i18n":[],"classification_confidence":"medium","classification_source":"domain-default","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","document_type":"article","domain":"geography-urban-planning","entities":["sg.agency.bca"],"facets":["current","geography","infrastructure","law","policy"],"geographic_scope":["national"],"jurisdiction":"SG","language":"en","last_verified":"2026-10-29","path":"geography-urban-planning\/concrete-identity-testing-sampling.md","related":["post-installed-anchor-safety","suspended-ceiling-safety","ura-and-master-plan"],"sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}],"status":"verified","summary":"BCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.","tags":["policy","regulation","public-safety","planning-area"],"temporal_scope":"current","title":"Concrete Identity-Testing Sampling Guidance","topics":["sgtopic.geography","sgtopic.geography-urban-planning.concrete-identity-testing-sampling"],"volatility":"fast"},"date":"2026-10-29","domain":"geography-urban-planning","evidence_paths":["source\/geography-urban-planning\/concrete-identity-testing-sampling.md","artefacts\/retrieval-chunks.jsonl","artefacts\/document-classification.jsonl"],"expected_version":12,"input_hash":"8bbe924bf9085f36507a74a1a36e889668243d5183696b9cfb73201cfe958093","kind":"article","lineage":[{"chunk_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling#overview","citation_urls":["https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"],"content_sha256":"bc10d037be5ea540a4f2ba863c1cb576b5fa9ab819c8cf9aeb635adeddea083f","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","section_sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]},{"chunk_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling#recommended-minimum-sampling-rates","citation_urls":["https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"],"content_sha256":"3ffaf89086a0451a13e3253a47921d82836c2dc9fdf71ea85bdf1e64296fb9c2","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","section_sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]},{"chunk_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling#how-to-read-the-stepped-baseline","citation_urls":["https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"],"content_sha256":"09511660cf05769748d8f74379e6365910af0676ab8313abd3efd8f143244af0","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","section_sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]},{"chunk_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling#qualified-person-discretion-and-additional-cubes","citation_urls":["https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"],"content_sha256":"4926aa8feeec825709f79c4d8e423b108ce94ef96218d7d7ba798a454b87d99d","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","section_sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]},{"chunk_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling#cube-size-and-interpretation-boundary","citation_urls":["https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"],"content_sha256":"fe61151717caa43eba22e0e304160b08cb0afa5ef18726daaa884d58f0ce8f62","document_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","document_sha256":"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8","section_sources":[{"accessed":"2026-10-29","published":"2026-09-01","publisher":"Building and Construction Authority","tier":1,"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]}],"links":[{"relation":"related","target_id":"sgkb.geography-urban-planning.post-installed-anchor-safety"},{"relation":"related","target_id":"sgkb.geography-urban-planning.suspended-ceiling-safety"},{"relation":"related","target_id":"sgkb.geography-urban-planning.ura-and-master-plan"},{"relation":"topics","target_id":"sgtopic.geography"},{"relation":"topics","target_id":"sgtopic.geography-urban-planning.concrete-identity-testing-sampling"},{"relation":"entities","target_id":"sg.agency.bca"}],"locales":{"en":{"markdown":"# Concrete Identity-Testing Sampling Guidance\n\nThe Building and Construction Authority (BCA) issued a circular on **1 September 2026** recommending a standardised minimum sampling rate for identity testing of concrete compressive strength. The circular applies to construction-industry practice where identity testing is performed and refers users to clause B.2(2), Annex B of SS EN 206. BCA says the guidance reflects the certification and quality-assurance maturity of Singapore's ready-mixed-concrete plants, while supporting more sustainable construction through fewer materials used for testing and less manpower ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Recommended minimum sampling rates\n\nThe circular recommends **one sample per 100 m\u00b3** for the first 400 m\u00b3 of concrete cast, **one sample per 200 m\u00b3** for the subsequent volume up to 2,500 m\u00b3, and **15 samples** for volumes above 2,500 m\u00b3. For bored piles, the recommendation is at least **one sample per pile**. Each sample should consist of at least four cube specimens, with two cubes used for 7-day testing and two for 28-day testing. These are common baseline recommendations where identity testing is performed, not a statement that every project has identical testing needs. BCA's annex provides worked totals in 100 m\u00b3 bands through 3,000 m\u00b3 to illustrate the stepped schedule ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## How to read the stepped baseline\n\nThe rate is progressive, not a flat requirement to take one sample for every 100 m\u00b3 throughout a project. BCA's worked annex shows four samples by 400 m\u00b3, five by 500 m\u00b3, and a total of 15 once the volume reaches 2,401\u20132,500 m\u00b3; the same 15-sample figure remains in the annex for the next 500 m\u00b3 bands. Bored piles have their own minimum of one sample per pile. The circular also distinguishes site identity testing from the production-control and conformity testing required of ready-mixed-concrete plants under their certification framework. The baseline therefore does not turn the 15-sample figure into a universal ceiling: the Qualified Person remains responsible for deciding whether the project, a critical element or a quality concern calls for additional tests ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Qualified Person discretion and additional cubes\n\nBCA expressly preserves the Qualified Person's (QP's) responsibility to determine whether additional sampling is necessary based on engineering judgement, project complexity or specific quality concerns. Higher sampling rates may be appropriate for critical structural elements such as transfer beams, long cantilevers, long-span beams, deep foundations or heavily loaded elements. Additional cubes may also be needed for prestressed-concrete strength verification before load transfer, formwork striking-time decisions, concrete-quality concerns, random verification tests, or special concretes such as high-strength, lightweight or self-compacting concrete. BCA also names structural complexity, load-critical elements, the QP's risk assessment and potential structural-safety consequences as relevant considerations ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Cube size and interpretation boundary\n\nThe circular recommends and encourages the use of **100 mm cube specimens** for conformity and identity testing where appropriate, noting that SS 544-1 permits them and that the identity criteria for 100 mm and 150 mm cubes are the same. BCA states that a 150 mm cube contains more than three times as much concrete as a 100 mm cube, creating material and transport benefits when the smaller specimen is suitable. The circular is a testing-rate and specimen guidance document; it does not replace the QP's engineering judgement, the applicable Building Control Regulations or the standards governing the specific project ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).","summary":"BCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.","title":"Concrete Identity-Testing Sampling Guidance"},"zh":{"markdown":"# \u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357\n\n\u5efa\u5c4b\u53d1\u5c55\u5c40\uff08BCA\uff09\u4e8e **2026 \u5e74\u4e5d\u6708 \u4e00\u65e5** \u53d1\u5e03\u901a\u544a\uff0c\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\u3002\u8be5\u901a\u544a\u9002\u7528\u4e8e\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u7684\u5efa\u7b51\u4e1a\u5b9e\u8df5\uff0c\u5e76\u63d0\u8bf7\u7528\u6237\u53c2\u9605 SS EN 206 \u9644\u5f55 B \u7b2c B.2(2) \u6761\u3002BCA \u8868\u793a\uff0c\u8fd9\u9879\u6307\u5357\u53cd\u6620\u4e86\u65b0\u52a0\u5761\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u8ba4\u8bc1\u548c\u8d28\u91cf\u4fdd\u8bc1\u65b9\u9762\u7684\u6210\u719f\u5ea6\uff0c\u540c\u65f6\u901a\u8fc7\u51cf\u5c11\u6d4b\u8bd5\u6240\u7528\u6750\u6599\u548c\u4eba\u529b\uff0c\u652f\u6301\u66f4\u53ef\u6301\u7eed\u7684\u5efa\u7b51\u65bd\u5de5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5efa\u8bae\u7684\u6700\u4f4e\u62bd\u6837\u7387\n\n\u8be5\u901a\u544a\u5efa\u8bae\uff0c\u5bf9\u6700\u521d\u6d47\u7b51\u7684 400 m\u00b3 \u6df7\u51dd\u571f\uff0c\u6bcf 100 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u5176\u540e\u81f3 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u6bcf 200 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u4e8e\u8d85\u8fc7 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u53d6 **15 \u4e2a\u6837\u672c**\u3002\u5bf9\u4e8e\u94bb\u5b54\u6869\uff0c\u5efa\u8bae\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 **\u4e00\u4e2a\u6837\u672c**\u3002\u6bcf\u4e2a\u6837\u672c\u5e94\u81f3\u5c11\u7531 \u56db\u4e2a\u7acb\u65b9\u4f53\u8bd5\u4ef6\u7ec4\u6210\uff0c\u5176\u4e2d \u4e24\u4e2a\u7acb\u65b9\u4f53\u7528\u4e8e 7 \u5929\u6d4b\u8bd5\uff0c\u53e6\u5916 \u4e24\u4e2a\u7528\u4e8e 28 \u5929\u6d4b\u8bd5\u3002\u8fd9\u4e9b\u662f\u5728\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u65f6\u9002\u7528\u7684\u901a\u7528\u57fa\u51c6\u5efa\u8bae\uff0c\u5e76\u4e0d\u8868\u793a\u6bcf\u4e2a\u9879\u76ee\u7684\u6d4b\u8bd5\u9700\u6c42\u90fd\u76f8\u540c\u3002BCA \u7684\u9644\u5f55\u6309\u6bcf 100 m\u00b3 \u4e3a\u4e00\u6863\u5217\u51fa\u622a\u81f3 3,000 m\u00b3 \u7684\u793a\u4f8b\u603b\u6570\uff0c\u4ee5\u8bf4\u660e\u5206\u6bb5\u9012\u589e\u7684\u5b89\u6392\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5982\u4f55\u7406\u89e3\u5206\u6bb5\u9012\u589e\u7684\u57fa\u51c6\n\n\u8be5\u62bd\u6837\u7387\u662f\u9010\u6bb5\u9012\u589e\u7684\uff0c\u5e76\u975e\u8981\u6c42\u5728\u6574\u4e2a\u9879\u76ee\u4e2d\u6bcf\u6d47\u7b51 100 m\u00b3 \u90fd\u53d6 \u4e00\u4e2a\u6837\u672c\u3002BCA \u7684\u793a\u4f8b\u9644\u5f55\u663e\u793a\uff0c\u6d47\u7b51\u91cf\u8fbe\u5230 400 m\u00b3 \u65f6\u5171\u53d6 \u56db\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 500 m\u00b3 \u65f6\u5171\u53d6 \u4e94\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 2,401\u20132,500 m\u00b3 \u65f6\u5171\u53d6 15 \u4e2a\u6837\u672c\uff1b\u9644\u5f55\u4e2d\u63a5\u4e0b\u6765\u7684\u6bcf\u4e2a 500 m\u00b3 \u6863\u4e5f\u7ef4\u6301 15 \u4e2a\u6837\u672c\u3002\u94bb\u5b54\u6869\u53e6\u6709\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 1 \u4e2a\u6837\u672c\u7684\u8981\u6c42\u3002\u8be5\u901a\u544a\u8fd8\u533a\u5206\u4e86\u73b0\u573a\u8eab\u4efd\u68c0\u9a8c\u4e0e\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u5176\u8ba4\u8bc1\u6846\u67b6\u4e0b\u5fc5\u987b\u8fdb\u884c\u7684\u751f\u4ea7\u63a7\u5236\u548c\u7b26\u5408\u6027\u6d4b\u8bd5\u3002\u56e0\u6b64\uff0c\u8fd9\u9879\u57fa\u51c6\u5e76\u672a\u5c06 15 \u4e2a\u6837\u672c\u5b9a\u4e3a\u666e\u904d\u4e0a\u9650\uff1a\u5408\u683c\u4eba\u58eb\u4ecd\u8d1f\u8d23\u5224\u65ad\u9879\u76ee\u3001\u5173\u952e\u6784\u4ef6\u6216\u8d28\u91cf\u95ee\u9898\u662f\u5426\u9700\u8981\u989d\u5916\u6d4b\u8bd5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5408\u683c\u4eba\u58eb\u7684\u914c\u60c5\u6743\u53ca\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\n\nBCA \u660e\u786e\u4fdd\u7559\u5408\u683c\u4eba\u58eb\uff08QP\uff09\u6839\u636e\u5de5\u7a0b\u5224\u65ad\u3001\u9879\u76ee\u590d\u6742\u7a0b\u5ea6\u6216\u5177\u4f53\u8d28\u91cf\u95ee\u9898\uff0c\u51b3\u5b9a\u662f\u5426\u9700\u8981\u989d\u5916\u62bd\u6837\u7684\u8d23\u4efb\u3002\u5bf9\u4e8e\u8f6c\u6362\u6881\u3001\u5927\u60ac\u81c2\u6881\u3001\u5927\u8de8\u5ea6\u6881\u3001\u6df1\u57fa\u7840\u6216\u627f\u53d7\u91cd\u8377\u8f7d\u7684\u6784\u4ef6\u7b49\u5173\u952e\u7ed3\u6784\u6784\u4ef6\uff0c\u91c7\u7528\u8f83\u9ad8\u62bd\u6837\u7387\u53ef\u80fd\u66f4\u5408\u9002\u3002\u5bf9\u4e8e\u9884\u5e94\u529b\u6df7\u51dd\u571f\u5728\u8377\u8f7d\u4f20\u9012\u524d\u7684\u5f3a\u5ea6\u9a8c\u8bc1\u3001\u51b3\u5b9a\u62c6\u6a21\u65f6\u95f4\u3001\u6df7\u51dd\u571f\u8d28\u91cf\u95ee\u9898\u3001\u968f\u673a\u9a8c\u8bc1\u6d4b\u8bd5\uff0c\u6216\u9ad8\u5f3a\u5ea6\u3001\u8f7b\u8d28\u6216\u81ea\u5bc6\u5b9e\u7b49\u7279\u6b8a\u6df7\u51dd\u571f\uff0c\u4e5f\u53ef\u80fd\u9700\u8981\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\u3002BCA \u8fd8\u6307\u51fa\uff0c\u7ed3\u6784\u590d\u6742\u7a0b\u5ea6\u3001\u8377\u8f7d\u5173\u952e\u6784\u4ef6\u3001QP \u7684\u98ce\u9669\u8bc4\u4f30\u4ee5\u53ca\u53ef\u80fd\u4ea7\u751f\u7684\u7ed3\u6784\u5b89\u5168\u540e\u679c\uff0c\u90fd\u662f\u76f8\u5173\u8003\u91cf\u56e0\u7d20\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u7acb\u65b9\u4f53\u5c3a\u5bf8\u4e0e\u9002\u7528\u8303\u56f4\n\n\u8be5\u901a\u544a\u5efa\u8bae\u5e76\u9f13\u52b1\u5728\u9002\u5f53\u60c5\u51b5\u4e0b\uff0c\u4f7f\u7528 **100 mm \u7acb\u65b9\u4f53\u8bd5\u4ef6**\u8fdb\u884c\u7b26\u5408\u6027\u548c\u8eab\u4efd\u68c0\u9a8c\uff1b\u901a\u544a\u6307\u51fa\uff0cSS 544-1 \u5141\u8bb8\u4f7f\u7528\u8fd9\u7c7b\u8bd5\u4ef6\uff0c\u800c\u4e14 100 mm \u548c 150 mm \u7acb\u65b9\u4f53\u7684\u8eab\u4efd\u68c0\u9a8c\u6807\u51c6\u76f8\u540c\u3002BCA \u8868\u793a\uff0c1 \u4e2a 150 mm \u7acb\u65b9\u4f53\u6240\u542b\u6df7\u51dd\u571f\u8d85\u8fc7 1 \u4e2a 100 mm \u7acb\u65b9\u4f53\u7684 \u4e09\u500d\uff1b\u5728\u8f83\u5c0f\u8bd5\u4ef6\u9002\u7528\u65f6\uff0c\u4f7f\u7528\u8f83\u5c0f\u8bd5\u4ef6\u53ef\u8282\u7701\u6750\u6599\u5e76\u5e26\u6765\u8fd0\u8f93\u6548\u76ca\u3002\u8be5\u901a\u544a\u662f\u5173\u4e8e\u6d4b\u8bd5\u7387\u548c\u8bd5\u4ef6\u7684\u6307\u5357\u6587\u4ef6\uff1b\u5b83\u4e0d\u4f1a\u53d6\u4ee3 QP \u7684\u5de5\u7a0b\u5224\u65ad\u3001\u9002\u7528\u7684\u300a\u5efa\u7b51\u7ba1\u5236\u6761\u4f8b\u300b\u6216\u5177\u4f53\u9879\u76ee\u6240\u9002\u7528\u7684\u6807\u51c6\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002","summary":"BCA \u4e8e 2026 \u5e74\u4e5d\u6708 1 \u65e5\u53d1\u5e03\u7684\u901a\u544a\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\uff0c\u540c\u65f6\u4fdd\u7559\u5408\u683c\u4eba\u58eb\u8981\u6c42\u8fdb\u884c\u989d\u5916\u6d4b\u8bd5\u7684\u914c\u60c5\u6743\u3002","title":"\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357"}},"source_id":"sgkb.geography-urban-planning.concrete-identity-testing-sampling","status":"verified","summary_en":"BCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.","summary_zh":"BCA \u4e8e 2026 \u5e74\u4e5d\u6708 1 \u65e5\u53d1\u5e03\u7684\u901a\u544a\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\uff0c\u540c\u65f6\u4fdd\u7559\u5408\u683c\u4eba\u58eb\u8981\u6c42\u8fdb\u884c\u989d\u5916\u6d4b\u8bd5\u7684\u914c\u60c5\u6743\u3002","title_en":"Concrete Identity-Testing Sampling Guidance","title_zh":"\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357","wiki":{"domain":"geography-urban-planning","last_verified":"2026-10-29","locales":{"en":{"markdown":"# Concrete Identity-Testing Sampling Guidance\n\nThe Building and Construction Authority (BCA) issued a circular on **1 September 2026** recommending a standardised minimum sampling rate for identity testing of concrete compressive strength. The circular applies to construction-industry practice where identity testing is performed and refers users to clause B.2(2), Annex B of SS EN 206. BCA says the guidance reflects the certification and quality-assurance maturity of Singapore's ready-mixed-concrete plants, while supporting more sustainable construction through fewer materials used for testing and less manpower ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Recommended minimum sampling rates\n\nThe circular recommends **one sample per 100 m\u00b3** for the first 400 m\u00b3 of concrete cast, **one sample per 200 m\u00b3** for the subsequent volume up to 2,500 m\u00b3, and **15 samples** for volumes above 2,500 m\u00b3. For bored piles, the recommendation is at least **one sample per pile**. Each sample should consist of at least four cube specimens, with two cubes used for 7-day testing and two for 28-day testing. These are common baseline recommendations where identity testing is performed, not a statement that every project has identical testing needs. BCA's annex provides worked totals in 100 m\u00b3 bands through 3,000 m\u00b3 to illustrate the stepped schedule ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## How to read the stepped baseline\n\nThe rate is progressive, not a flat requirement to take one sample for every 100 m\u00b3 throughout a project. BCA's worked annex shows four samples by 400 m\u00b3, five by 500 m\u00b3, and a total of 15 once the volume reaches 2,401\u20132,500 m\u00b3; the same 15-sample figure remains in the annex for the next 500 m\u00b3 bands. Bored piles have their own minimum of one sample per pile. The circular also distinguishes site identity testing from the production-control and conformity testing required of ready-mixed-concrete plants under their certification framework. The baseline therefore does not turn the 15-sample figure into a universal ceiling: the Qualified Person remains responsible for deciding whether the project, a critical element or a quality concern calls for additional tests ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Qualified Person discretion and additional cubes\n\nBCA expressly preserves the Qualified Person's (QP's) responsibility to determine whether additional sampling is necessary based on engineering judgement, project complexity or specific quality concerns. Higher sampling rates may be appropriate for critical structural elements such as transfer beams, long cantilevers, long-span beams, deep foundations or heavily loaded elements. Additional cubes may also be needed for prestressed-concrete strength verification before load transfer, formwork striking-time decisions, concrete-quality concerns, random verification tests, or special concretes such as high-strength, lightweight or self-compacting concrete. BCA also names structural complexity, load-critical elements, the QP's risk assessment and potential structural-safety consequences as relevant considerations ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Cube size and interpretation boundary\n\nThe circular recommends and encourages the use of **100 mm cube specimens** for conformity and identity testing where appropriate, noting that SS 544-1 permits them and that the identity criteria for 100 mm and 150 mm cubes are the same. BCA states that a 150 mm cube contains more than three times as much concrete as a 100 mm cube, creating material and transport benefits when the smaller specimen is suitable. The circular is a testing-rate and specimen guidance document; it does not replace the QP's engineering judgement, the applicable Building Control Regulations or the standards governing the specific project ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).","summary":"BCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.","title":"Concrete Identity-Testing Sampling Guidance"},"zh":{"markdown":"# \u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357\n\n\u5efa\u5c4b\u53d1\u5c55\u5c40\uff08BCA\uff09\u4e8e **2026 \u5e74\u4e5d\u6708 \u4e00\u65e5** \u53d1\u5e03\u901a\u544a\uff0c\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\u3002\u8be5\u901a\u544a\u9002\u7528\u4e8e\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u7684\u5efa\u7b51\u4e1a\u5b9e\u8df5\uff0c\u5e76\u63d0\u8bf7\u7528\u6237\u53c2\u9605 SS EN 206 \u9644\u5f55 B \u7b2c B.2(2) \u6761\u3002BCA \u8868\u793a\uff0c\u8fd9\u9879\u6307\u5357\u53cd\u6620\u4e86\u65b0\u52a0\u5761\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u8ba4\u8bc1\u548c\u8d28\u91cf\u4fdd\u8bc1\u65b9\u9762\u7684\u6210\u719f\u5ea6\uff0c\u540c\u65f6\u901a\u8fc7\u51cf\u5c11\u6d4b\u8bd5\u6240\u7528\u6750\u6599\u548c\u4eba\u529b\uff0c\u652f\u6301\u66f4\u53ef\u6301\u7eed\u7684\u5efa\u7b51\u65bd\u5de5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5efa\u8bae\u7684\u6700\u4f4e\u62bd\u6837\u7387\n\n\u8be5\u901a\u544a\u5efa\u8bae\uff0c\u5bf9\u6700\u521d\u6d47\u7b51\u7684 400 m\u00b3 \u6df7\u51dd\u571f\uff0c\u6bcf 100 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u5176\u540e\u81f3 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u6bcf 200 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u4e8e\u8d85\u8fc7 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u53d6 **15 \u4e2a\u6837\u672c**\u3002\u5bf9\u4e8e\u94bb\u5b54\u6869\uff0c\u5efa\u8bae\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 **\u4e00\u4e2a\u6837\u672c**\u3002\u6bcf\u4e2a\u6837\u672c\u5e94\u81f3\u5c11\u7531 \u56db\u4e2a\u7acb\u65b9\u4f53\u8bd5\u4ef6\u7ec4\u6210\uff0c\u5176\u4e2d \u4e24\u4e2a\u7acb\u65b9\u4f53\u7528\u4e8e 7 \u5929\u6d4b\u8bd5\uff0c\u53e6\u5916 \u4e24\u4e2a\u7528\u4e8e 28 \u5929\u6d4b\u8bd5\u3002\u8fd9\u4e9b\u662f\u5728\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u65f6\u9002\u7528\u7684\u901a\u7528\u57fa\u51c6\u5efa\u8bae\uff0c\u5e76\u4e0d\u8868\u793a\u6bcf\u4e2a\u9879\u76ee\u7684\u6d4b\u8bd5\u9700\u6c42\u90fd\u76f8\u540c\u3002BCA \u7684\u9644\u5f55\u6309\u6bcf 100 m\u00b3 \u4e3a\u4e00\u6863\u5217\u51fa\u622a\u81f3 3,000 m\u00b3 \u7684\u793a\u4f8b\u603b\u6570\uff0c\u4ee5\u8bf4\u660e\u5206\u6bb5\u9012\u589e\u7684\u5b89\u6392\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5982\u4f55\u7406\u89e3\u5206\u6bb5\u9012\u589e\u7684\u57fa\u51c6\n\n\u8be5\u62bd\u6837\u7387\u662f\u9010\u6bb5\u9012\u589e\u7684\uff0c\u5e76\u975e\u8981\u6c42\u5728\u6574\u4e2a\u9879\u76ee\u4e2d\u6bcf\u6d47\u7b51 100 m\u00b3 \u90fd\u53d6 \u4e00\u4e2a\u6837\u672c\u3002BCA \u7684\u793a\u4f8b\u9644\u5f55\u663e\u793a\uff0c\u6d47\u7b51\u91cf\u8fbe\u5230 400 m\u00b3 \u65f6\u5171\u53d6 \u56db\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 500 m\u00b3 \u65f6\u5171\u53d6 \u4e94\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 2,401\u20132,500 m\u00b3 \u65f6\u5171\u53d6 15 \u4e2a\u6837\u672c\uff1b\u9644\u5f55\u4e2d\u63a5\u4e0b\u6765\u7684\u6bcf\u4e2a 500 m\u00b3 \u6863\u4e5f\u7ef4\u6301 15 \u4e2a\u6837\u672c\u3002\u94bb\u5b54\u6869\u53e6\u6709\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 1 \u4e2a\u6837\u672c\u7684\u8981\u6c42\u3002\u8be5\u901a\u544a\u8fd8\u533a\u5206\u4e86\u73b0\u573a\u8eab\u4efd\u68c0\u9a8c\u4e0e\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u5176\u8ba4\u8bc1\u6846\u67b6\u4e0b\u5fc5\u987b\u8fdb\u884c\u7684\u751f\u4ea7\u63a7\u5236\u548c\u7b26\u5408\u6027\u6d4b\u8bd5\u3002\u56e0\u6b64\uff0c\u8fd9\u9879\u57fa\u51c6\u5e76\u672a\u5c06 15 \u4e2a\u6837\u672c\u5b9a\u4e3a\u666e\u904d\u4e0a\u9650\uff1a\u5408\u683c\u4eba\u58eb\u4ecd\u8d1f\u8d23\u5224\u65ad\u9879\u76ee\u3001\u5173\u952e\u6784\u4ef6\u6216\u8d28\u91cf\u95ee\u9898\u662f\u5426\u9700\u8981\u989d\u5916\u6d4b\u8bd5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5408\u683c\u4eba\u58eb\u7684\u914c\u60c5\u6743\u53ca\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\n\nBCA \u660e\u786e\u4fdd\u7559\u5408\u683c\u4eba\u58eb\uff08QP\uff09\u6839\u636e\u5de5\u7a0b\u5224\u65ad\u3001\u9879\u76ee\u590d\u6742\u7a0b\u5ea6\u6216\u5177\u4f53\u8d28\u91cf\u95ee\u9898\uff0c\u51b3\u5b9a\u662f\u5426\u9700\u8981\u989d\u5916\u62bd\u6837\u7684\u8d23\u4efb\u3002\u5bf9\u4e8e\u8f6c\u6362\u6881\u3001\u5927\u60ac\u81c2\u6881\u3001\u5927\u8de8\u5ea6\u6881\u3001\u6df1\u57fa\u7840\u6216\u627f\u53d7\u91cd\u8377\u8f7d\u7684\u6784\u4ef6\u7b49\u5173\u952e\u7ed3\u6784\u6784\u4ef6\uff0c\u91c7\u7528\u8f83\u9ad8\u62bd\u6837\u7387\u53ef\u80fd\u66f4\u5408\u9002\u3002\u5bf9\u4e8e\u9884\u5e94\u529b\u6df7\u51dd\u571f\u5728\u8377\u8f7d\u4f20\u9012\u524d\u7684\u5f3a\u5ea6\u9a8c\u8bc1\u3001\u51b3\u5b9a\u62c6\u6a21\u65f6\u95f4\u3001\u6df7\u51dd\u571f\u8d28\u91cf\u95ee\u9898\u3001\u968f\u673a\u9a8c\u8bc1\u6d4b\u8bd5\uff0c\u6216\u9ad8\u5f3a\u5ea6\u3001\u8f7b\u8d28\u6216\u81ea\u5bc6\u5b9e\u7b49\u7279\u6b8a\u6df7\u51dd\u571f\uff0c\u4e5f\u53ef\u80fd\u9700\u8981\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\u3002BCA \u8fd8\u6307\u51fa\uff0c\u7ed3\u6784\u590d\u6742\u7a0b\u5ea6\u3001\u8377\u8f7d\u5173\u952e\u6784\u4ef6\u3001QP \u7684\u98ce\u9669\u8bc4\u4f30\u4ee5\u53ca\u53ef\u80fd\u4ea7\u751f\u7684\u7ed3\u6784\u5b89\u5168\u540e\u679c\uff0c\u90fd\u662f\u76f8\u5173\u8003\u91cf\u56e0\u7d20\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u7acb\u65b9\u4f53\u5c3a\u5bf8\u4e0e\u9002\u7528\u8303\u56f4\n\n\u8be5\u901a\u544a\u5efa\u8bae\u5e76\u9f13\u52b1\u5728\u9002\u5f53\u60c5\u51b5\u4e0b\uff0c\u4f7f\u7528 **100 mm \u7acb\u65b9\u4f53\u8bd5\u4ef6**\u8fdb\u884c\u7b26\u5408\u6027\u548c\u8eab\u4efd\u68c0\u9a8c\uff1b\u901a\u544a\u6307\u51fa\uff0cSS 544-1 \u5141\u8bb8\u4f7f\u7528\u8fd9\u7c7b\u8bd5\u4ef6\uff0c\u800c\u4e14 100 mm \u548c 150 mm \u7acb\u65b9\u4f53\u7684\u8eab\u4efd\u68c0\u9a8c\u6807\u51c6\u76f8\u540c\u3002BCA \u8868\u793a\uff0c1 \u4e2a 150 mm \u7acb\u65b9\u4f53\u6240\u542b\u6df7\u51dd\u571f\u8d85\u8fc7 1 \u4e2a 100 mm \u7acb\u65b9\u4f53\u7684 \u4e09\u500d\uff1b\u5728\u8f83\u5c0f\u8bd5\u4ef6\u9002\u7528\u65f6\uff0c\u4f7f\u7528\u8f83\u5c0f\u8bd5\u4ef6\u53ef\u8282\u7701\u6750\u6599\u5e76\u5e26\u6765\u8fd0\u8f93\u6548\u76ca\u3002\u8be5\u901a\u544a\u662f\u5173\u4e8e\u6d4b\u8bd5\u7387\u548c\u8bd5\u4ef6\u7684\u6307\u5357\u6587\u4ef6\uff1b\u5b83\u4e0d\u4f1a\u53d6\u4ee3 QP \u7684\u5de5\u7a0b\u5224\u65ad\u3001\u9002\u7528\u7684\u300a\u5efa\u7b51\u7ba1\u5236\u6761\u4f8b\u300b\u6216\u5177\u4f53\u9879\u76ee\u6240\u9002\u7528\u7684\u6807\u51c6\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002","summary":"BCA \u4e8e 2026 \u5e74\u4e5d\u6708 1 \u65e5\u53d1\u5e03\u7684\u901a\u544a\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\uff0c\u540c\u65f6\u4fdd\u7559\u5408\u683c\u4eba\u58eb\u8981\u6c42\u8fdb\u884c\u989d\u5916\u6d4b\u8bd5\u7684\u914c\u60c5\u6743\u3002","title":"\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357"}},"path":"geography-urban-planning\/concrete-identity-testing-sampling.md","related_source_ids":["sgkb.geography-urban-planning.post-installed-anchor-safety","sgkb.geography-urban-planning.suspended-ceiling-safety","sgkb.geography-urban-planning.ura-and-master-plan"],"source_hash":"8bbe924bf9085f36507a74a1a36e889668243d5183696b9cfb73201cfe958093","source_revision":"094b7bf3a1ab75da7b1952ee33089c1733835fe6","sources":[{"title":"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete","url":"https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1"}]}},"search_text":"Concrete Identity-Testing Sampling Guidance\n\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357\nBCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.\nBCA \u4e8e 2026 \u5e74\u4e5d\u6708 1 \u65e5\u53d1\u5e03\u7684\u901a\u544a\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\uff0c\u540c\u65f6\u4fdd\u7559\u5408\u683c\u4eba\u58eb\u8981\u6c42\u8fdb\u884c\u989d\u5916\u6d4b\u8bd5\u7684\u914c\u60c5\u6743\u3002\n{\"aliases\":[\"concrete identity testing Singapore\",\"concrete compressive strength sampling\",\"BCA concrete sampling rate\"],\"aliases_i18n\":[],\"classification_confidence\":\"medium\",\"classification_source\":\"domain-default\",\"document_id\":\"sgkb.geography-urban-planning.concrete-identity-testing-sampling\",\"document_sha256\":\"3c5e50eaae81177497c2728d51fc3aaf28dd1025b9272a20bc9881bc0972eaa8\",\"document_type\":\"article\",\"domain\":\"geography-urban-planning\",\"entities\":[\"sg.agency.bca\"],\"facets\":[\"current\",\"geography\",\"infrastructure\",\"law\",\"policy\"],\"geographic_scope\":[\"national\"],\"jurisdiction\":\"SG\",\"language\":\"en\",\"last_verified\":\"2026-10-29\",\"path\":\"geography-urban-planning\\\/concrete-identity-testing-sampling.md\",\"related\":[\"post-installed-anchor-safety\",\"suspended-ceiling-safety\",\"ura-and-master-plan\"],\"sources\":[{\"accessed\":\"2026-10-29\",\"published\":\"2026-09-01\",\"publisher\":\"Building and Construction Authority\",\"tier\":1,\"title\":\"BCA \u2014 Standardised Sampling Rate: Identity Testing for Compressive Strength of Concrete\",\"url\":\"https:\\\/\\\/info.corenet.gov.sg\\\/docs\\\/default-source\\\/bca-circulars\\\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1\"}],\"status\":\"verified\",\"summary\":\"BCA's 1 September 2026 circular recommends standardised minimum sampling rates for identity testing of concrete compressive strength while preserving Qualified Person discretion to require additional testing.\",\"tags\":[\"policy\",\"regulation\",\"public-safety\",\"planning-area\"],\"temporal_scope\":\"current\",\"title\":\"Concrete Identity-Testing Sampling Guidance\",\"topics\":[\"sgtopic.geography\",\"sgtopic.geography-urban-planning.concrete-identity-testing-sampling\"],\"volatility\":\"fast\"}\n# Concrete Identity-Testing Sampling Guidance\n\nThe Building and Construction Authority (BCA) issued a circular on **1 September 2026** recommending a standardised minimum sampling rate for identity testing of concrete compressive strength. The circular applies to construction-industry practice where identity testing is performed and refers users to clause B.2(2), Annex B of SS EN 206. BCA says the guidance reflects the certification and quality-assurance maturity of Singapore's ready-mixed-concrete plants, while supporting more sustainable construction through fewer materials used for testing and less manpower ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Recommended minimum sampling rates\n\nThe circular recommends **one sample per 100 m\u00b3** for the first 400 m\u00b3 of concrete cast, **one sample per 200 m\u00b3** for the subsequent volume up to 2,500 m\u00b3, and **15 samples** for volumes above 2,500 m\u00b3. For bored piles, the recommendation is at least **one sample per pile**. Each sample should consist of at least four cube specimens, with two cubes used for 7-day testing and two for 28-day testing. These are common baseline recommendations where identity testing is performed, not a statement that every project has identical testing needs. BCA's annex provides worked totals in 100 m\u00b3 bands through 3,000 m\u00b3 to illustrate the stepped schedule ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## How to read the stepped baseline\n\nThe rate is progressive, not a flat requirement to take one sample for every 100 m\u00b3 throughout a project. BCA's worked annex shows four samples by 400 m\u00b3, five by 500 m\u00b3, and a total of 15 once the volume reaches 2,401\u20132,500 m\u00b3; the same 15-sample figure remains in the annex for the next 500 m\u00b3 bands. Bored piles have their own minimum of one sample per pile. The circular also distinguishes site identity testing from the production-control and conformity testing required of ready-mixed-concrete plants under their certification framework. The baseline therefore does not turn the 15-sample figure into a universal ceiling: the Qualified Person remains responsible for deciding whether the project, a critical element or a quality concern calls for additional tests ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Qualified Person discretion and additional cubes\n\nBCA expressly preserves the Qualified Person's (QP's) responsibility to determine whether additional sampling is necessary based on engineering judgement, project complexity or specific quality concerns. Higher sampling rates may be appropriate for critical structural elements such as transfer beams, long cantilevers, long-span beams, deep foundations or heavily loaded elements. Additional cubes may also be needed for prestressed-concrete strength verification before load transfer, formwork striking-time decisions, concrete-quality concerns, random verification tests, or special concretes such as high-strength, lightweight or self-compacting concrete. BCA also names structural complexity, load-critical elements, the QP's risk assessment and potential structural-safety consequences as relevant considerations ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n\n## Cube size and interpretation boundary\n\nThe circular recommends and encourages the use of **100 mm cube specimens** for conformity and identity testing where appropriate, noting that SS 544-1 permits them and that the identity criteria for 100 mm and 150 mm cubes are the same. BCA states that a 150 mm cube contains more than three times as much concrete as a 100 mm cube, creating material and transport benefits when the smaller specimen is suitable. The circular is a testing-rate and specimen guidance document; it does not replace the QP's engineering judgement, the applicable Building Control Regulations or the standards governing the specific project ([BCA, 1 September 2026](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)).\n# \u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u9a8c\u62bd\u6837\u6307\u5357\n\n\u5efa\u5c4b\u53d1\u5c55\u5c40\uff08BCA\uff09\u4e8e **2026 \u5e74\u4e5d\u6708 \u4e00\u65e5** \u53d1\u5e03\u901a\u544a\uff0c\u5efa\u8bae\u91c7\u7528\u6807\u51c6\u5316\u7684\u6df7\u51dd\u571f\u6297\u538b\u5f3a\u5ea6\u8eab\u4efd\u68c0\u9a8c\u6700\u4f4e\u62bd\u6837\u7387\u3002\u8be5\u901a\u544a\u9002\u7528\u4e8e\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u7684\u5efa\u7b51\u4e1a\u5b9e\u8df5\uff0c\u5e76\u63d0\u8bf7\u7528\u6237\u53c2\u9605 SS EN 206 \u9644\u5f55 B \u7b2c B.2(2) \u6761\u3002BCA \u8868\u793a\uff0c\u8fd9\u9879\u6307\u5357\u53cd\u6620\u4e86\u65b0\u52a0\u5761\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u8ba4\u8bc1\u548c\u8d28\u91cf\u4fdd\u8bc1\u65b9\u9762\u7684\u6210\u719f\u5ea6\uff0c\u540c\u65f6\u901a\u8fc7\u51cf\u5c11\u6d4b\u8bd5\u6240\u7528\u6750\u6599\u548c\u4eba\u529b\uff0c\u652f\u6301\u66f4\u53ef\u6301\u7eed\u7684\u5efa\u7b51\u65bd\u5de5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5efa\u8bae\u7684\u6700\u4f4e\u62bd\u6837\u7387\n\n\u8be5\u901a\u544a\u5efa\u8bae\uff0c\u5bf9\u6700\u521d\u6d47\u7b51\u7684 400 m\u00b3 \u6df7\u51dd\u571f\uff0c\u6bcf 100 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u5176\u540e\u81f3 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u6bcf 200 m\u00b3 \u53d6 **\u4e00\u4e2a\u6837\u672c**\uff1b\u5bf9\u4e8e\u8d85\u8fc7 2,500 m\u00b3 \u7684\u4f53\u79ef\uff0c\u53d6 **15 \u4e2a\u6837\u672c**\u3002\u5bf9\u4e8e\u94bb\u5b54\u6869\uff0c\u5efa\u8bae\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 **\u4e00\u4e2a\u6837\u672c**\u3002\u6bcf\u4e2a\u6837\u672c\u5e94\u81f3\u5c11\u7531 \u56db\u4e2a\u7acb\u65b9\u4f53\u8bd5\u4ef6\u7ec4\u6210\uff0c\u5176\u4e2d \u4e24\u4e2a\u7acb\u65b9\u4f53\u7528\u4e8e 7 \u5929\u6d4b\u8bd5\uff0c\u53e6\u5916 \u4e24\u4e2a\u7528\u4e8e 28 \u5929\u6d4b\u8bd5\u3002\u8fd9\u4e9b\u662f\u5728\u8fdb\u884c\u8eab\u4efd\u68c0\u9a8c\u65f6\u9002\u7528\u7684\u901a\u7528\u57fa\u51c6\u5efa\u8bae\uff0c\u5e76\u4e0d\u8868\u793a\u6bcf\u4e2a\u9879\u76ee\u7684\u6d4b\u8bd5\u9700\u6c42\u90fd\u76f8\u540c\u3002BCA \u7684\u9644\u5f55\u6309\u6bcf 100 m\u00b3 \u4e3a\u4e00\u6863\u5217\u51fa\u622a\u81f3 3,000 m\u00b3 \u7684\u793a\u4f8b\u603b\u6570\uff0c\u4ee5\u8bf4\u660e\u5206\u6bb5\u9012\u589e\u7684\u5b89\u6392\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 \u4e00\u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5982\u4f55\u7406\u89e3\u5206\u6bb5\u9012\u589e\u7684\u57fa\u51c6\n\n\u8be5\u62bd\u6837\u7387\u662f\u9010\u6bb5\u9012\u589e\u7684\uff0c\u5e76\u975e\u8981\u6c42\u5728\u6574\u4e2a\u9879\u76ee\u4e2d\u6bcf\u6d47\u7b51 100 m\u00b3 \u90fd\u53d6 \u4e00\u4e2a\u6837\u672c\u3002BCA \u7684\u793a\u4f8b\u9644\u5f55\u663e\u793a\uff0c\u6d47\u7b51\u91cf\u8fbe\u5230 400 m\u00b3 \u65f6\u5171\u53d6 \u56db\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 500 m\u00b3 \u65f6\u5171\u53d6 \u4e94\u4e2a\u6837\u672c\uff0c\u8fbe\u5230 2,401\u20132,500 m\u00b3 \u65f6\u5171\u53d6 15 \u4e2a\u6837\u672c\uff1b\u9644\u5f55\u4e2d\u63a5\u4e0b\u6765\u7684\u6bcf\u4e2a 500 m\u00b3 \u6863\u4e5f\u7ef4\u6301 15 \u4e2a\u6837\u672c\u3002\u94bb\u5b54\u6869\u53e6\u6709\u6bcf\u6839\u6869\u81f3\u5c11\u53d6 1 \u4e2a\u6837\u672c\u7684\u8981\u6c42\u3002\u8be5\u901a\u544a\u8fd8\u533a\u5206\u4e86\u73b0\u573a\u8eab\u4efd\u68c0\u9a8c\u4e0e\u9884\u62cc\u6df7\u51dd\u571f\u5382\u5728\u5176\u8ba4\u8bc1\u6846\u67b6\u4e0b\u5fc5\u987b\u8fdb\u884c\u7684\u751f\u4ea7\u63a7\u5236\u548c\u7b26\u5408\u6027\u6d4b\u8bd5\u3002\u56e0\u6b64\uff0c\u8fd9\u9879\u57fa\u51c6\u5e76\u672a\u5c06 15 \u4e2a\u6837\u672c\u5b9a\u4e3a\u666e\u904d\u4e0a\u9650\uff1a\u5408\u683c\u4eba\u58eb\u4ecd\u8d1f\u8d23\u5224\u65ad\u9879\u76ee\u3001\u5173\u952e\u6784\u4ef6\u6216\u8d28\u91cf\u95ee\u9898\u662f\u5426\u9700\u8981\u989d\u5916\u6d4b\u8bd5\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u5408\u683c\u4eba\u58eb\u7684\u914c\u60c5\u6743\u53ca\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\n\nBCA \u660e\u786e\u4fdd\u7559\u5408\u683c\u4eba\u58eb\uff08QP\uff09\u6839\u636e\u5de5\u7a0b\u5224\u65ad\u3001\u9879\u76ee\u590d\u6742\u7a0b\u5ea6\u6216\u5177\u4f53\u8d28\u91cf\u95ee\u9898\uff0c\u51b3\u5b9a\u662f\u5426\u9700\u8981\u989d\u5916\u62bd\u6837\u7684\u8d23\u4efb\u3002\u5bf9\u4e8e\u8f6c\u6362\u6881\u3001\u5927\u60ac\u81c2\u6881\u3001\u5927\u8de8\u5ea6\u6881\u3001\u6df1\u57fa\u7840\u6216\u627f\u53d7\u91cd\u8377\u8f7d\u7684\u6784\u4ef6\u7b49\u5173\u952e\u7ed3\u6784\u6784\u4ef6\uff0c\u91c7\u7528\u8f83\u9ad8\u62bd\u6837\u7387\u53ef\u80fd\u66f4\u5408\u9002\u3002\u5bf9\u4e8e\u9884\u5e94\u529b\u6df7\u51dd\u571f\u5728\u8377\u8f7d\u4f20\u9012\u524d\u7684\u5f3a\u5ea6\u9a8c\u8bc1\u3001\u51b3\u5b9a\u62c6\u6a21\u65f6\u95f4\u3001\u6df7\u51dd\u571f\u8d28\u91cf\u95ee\u9898\u3001\u968f\u673a\u9a8c\u8bc1\u6d4b\u8bd5\uff0c\u6216\u9ad8\u5f3a\u5ea6\u3001\u8f7b\u8d28\u6216\u81ea\u5bc6\u5b9e\u7b49\u7279\u6b8a\u6df7\u51dd\u571f\uff0c\u4e5f\u53ef\u80fd\u9700\u8981\u989d\u5916\u7acb\u65b9\u4f53\u8bd5\u4ef6\u3002BCA \u8fd8\u6307\u51fa\uff0c\u7ed3\u6784\u590d\u6742\u7a0b\u5ea6\u3001\u8377\u8f7d\u5173\u952e\u6784\u4ef6\u3001QP \u7684\u98ce\u9669\u8bc4\u4f30\u4ee5\u53ca\u53ef\u80fd\u4ea7\u751f\u7684\u7ed3\u6784\u5b89\u5168\u540e\u679c\uff0c\u90fd\u662f\u76f8\u5173\u8003\u91cf\u56e0\u7d20\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002\n\n## \u7acb\u65b9\u4f53\u5c3a\u5bf8\u4e0e\u9002\u7528\u8303\u56f4\n\n\u8be5\u901a\u544a\u5efa\u8bae\u5e76\u9f13\u52b1\u5728\u9002\u5f53\u60c5\u51b5\u4e0b\uff0c\u4f7f\u7528 **100 mm \u7acb\u65b9\u4f53\u8bd5\u4ef6**\u8fdb\u884c\u7b26\u5408\u6027\u548c\u8eab\u4efd\u68c0\u9a8c\uff1b\u901a\u544a\u6307\u51fa\uff0cSS 544-1 \u5141\u8bb8\u4f7f\u7528\u8fd9\u7c7b\u8bd5\u4ef6\uff0c\u800c\u4e14 100 mm \u548c 150 mm \u7acb\u65b9\u4f53\u7684\u8eab\u4efd\u68c0\u9a8c\u6807\u51c6\u76f8\u540c\u3002BCA \u8868\u793a\uff0c1 \u4e2a 150 mm \u7acb\u65b9\u4f53\u6240\u542b\u6df7\u51dd\u571f\u8d85\u8fc7 1 \u4e2a 100 mm \u7acb\u65b9\u4f53\u7684 \u4e09\u500d\uff1b\u5728\u8f83\u5c0f\u8bd5\u4ef6\u9002\u7528\u65f6\uff0c\u4f7f\u7528\u8f83\u5c0f\u8bd5\u4ef6\u53ef\u8282\u7701\u6750\u6599\u5e76\u5e26\u6765\u8fd0\u8f93\u6548\u76ca\u3002\u8be5\u901a\u544a\u662f\u5173\u4e8e\u6d4b\u8bd5\u7387\u548c\u8bd5\u4ef6\u7684\u6307\u5357\u6587\u4ef6\uff1b\u5b83\u4e0d\u4f1a\u53d6\u4ee3 QP \u7684\u5de5\u7a0b\u5224\u65ad\u3001\u9002\u7528\u7684\u300a\u5efa\u7b51\u7ba1\u5236\u6761\u4f8b\u300b\u6216\u5177\u4f53\u9879\u76ee\u6240\u9002\u7528\u7684\u6807\u51c6\uff08[BCA\uff0c2026 \u5e74\u4e5d\u6708 1 \u65e5](https:\/\/info.corenet.gov.sg\/docs\/default-source\/bca-circulars\/20260901---standardised-sampling-rate---identity-testing-for-compressive-strength-of-concrete.pdf?sfvrsn=6c5a049d_1)\uff09\u3002"},"related":[{"id":90413,"source_id":"sgkb.geography-urban-planning.granite-fines-concrete-specification-2026","kind":"article","title_en":"Granite Fines for Concrete: BCA Specification and Research","title_zh":"\u6df7\u51dd\u571f\u7528\u82b1\u5c97\u5ca9\u7ec6\u6599\uff1aBCA\u89c4\u8303\u4e0e\u7814\u7a76","assurance":null,"subtype":null},{"id":90416,"source_id":"sgkb.geography-urban-planning.importers-licensing-essential-construction-materials-2026","kind":"article","title_en":"Importers' Licensing Scheme for Essential Construction Materials","title_zh":"\u91cd\u8981\u5efa\u7b51\u6750\u6599\u8fdb\u53e3\u5546\u8bb8\u53ef\u8ba1\u5212","assurance":null,"subtype":null},{"id":90427,"source_id":"sgkb.geography-urban-planning.post-installed-anchor-safety","kind":"article","title_en":"Post-Installed Anchor Safety Guidance","title_zh":"\u540e\u7f6e\u951a\u6813\u5b89\u5168\u6307\u5357","assurance":null,"subtype":null},{"id":90428,"source_id":"sgkb.geography-urban-planning.pre-construction-survey-guidelines-2026","kind":"article","title_en":"Pre-Construction Survey Guidelines","title_zh":"\u65bd\u5de5\u524d\u52d8\u5bdf\u6307\u5357","assurance":null,"subtype":null},{"id":90436,"source_id":"sgkb.geography-urban-planning.suspended-ceiling-safety","kind":"article","title_en":"Suspended Ceiling Safety Advisory","title_zh":"\u60ac\u6302\u5f0f\u5929\u82b1\u677f\u5b89\u5168\u901a\u544a","assurance":null,"subtype":null},{"id":90437,"source_id":"sgkb.geography-urban-planning.ura-and-master-plan","kind":"article","title_en":"URA and the Master Plan","title_zh":"\u5e02\u533a\u91cd\u5efa\u5c40\u4e0e\u603b\u4f53\u89c4\u5212","assurance":null,"subtype":null},{"id":79783,"source_id":"sg.agency.bca","kind":"entity","title_en":"Building and Construction Authority","title_zh":"\u5efa\u8bbe\u5c40","assurance":null,"subtype":"agency"},{"id":92608,"source_id":"sgtopic.geography-urban-planning.concrete-identity-testing-sampling","kind":"topic","title_en":"Concrete Identity-Testing Sampling Guidance","title_zh":"\u6df7\u51dd\u571f\u8eab\u4efd\u68c0\u6d4b\u53d6\u6837\u6307\u5357","assurance":null,"subtype":null},{"id":92636,"source_id":"sgtopic.geography","kind":"topic","title_en":"Geography and urban planning","title_zh":"\u5730\u7406\u4e0e\u57ce\u5e02\u89c4\u5212","assurance":null,"subtype":null}]}